Flow rate range (Typical):<\/span> 1 1/2" (40 A): 400 L / min 100 gal / min 24 m<\/span>3<\/span>/ h)<\/span> 2" (50 A): 600 L / min 150 gal / min 36 m<\/span>3<\/span> / h<\/span><\/p><\/td>
Zero cut: 0.3 m/s (default)<\/span>*3<\/span> Flow rate (Typical): 36 L / min 9 gal / min 2.4 m<\/span>3<\/span> / h<\/span><\/p><\/td>
Zero cut: 0.3 m/s (default)<\/span>*3<\/span> Flow rate (Typical): 90 L / min 24 gal / min 5.4 m<\/span>3<\/span>/h<\/span><\/p><\/td>
Zero cut: 0.3 m/s (default)<\/span>*3<\/span> Flow rate (Typical): 220 L / min 60 gal / min 12 m<\/span>3<\/span>/h<\/span><\/p><\/td>
Zero cut: 0.3 m/s (default)<\/span>*3<\/span> Flow rate (Typical): 570 L / min 150 gal / min 36 m<\/span>3<\/span> / h<\/span><\/p><\/td><\/tr>
Display method<\/span><\/p><\/td>
Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator<\/span><\/p><\/td><\/tr>
Display update cycle<\/span><\/p><\/td>
Approx. 3 Hz<\/span><\/p><\/td><\/tr>
Display resolution<\/span><\/p><\/td>
0.1 / 1 (L / min)<\/span><\/p><\/td>
1 (L / min)<\/span><\/p><\/td><\/tr>
Response time<\/span><\/p><\/td>
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)<\/span><\/p><\/td><\/tr>
Measurement accuracy<\/span><\/p><\/td>
Between 20 and 100% of F.S. : ±2.0% of RD<\/span>*4*5<\/span> Between 6 and 20% of F.S. : ±0.4% of F.S. <\/span>*4*5<\/span><\/p><\/td><\/tr>
Protection circuit<\/span><\/p><\/td>
Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output<\/span><\/p><\/td><\/tr>
Zero point error<\/span><\/p><\/td>
±0.5% of F.S.<\/span>*4*6<\/span><\/p><\/td><\/tr>
Hysteresis<\/span><\/p><\/td>
Variable<\/span><\/p><\/td><\/tr>
Flow units<\/span><\/p><\/td>
L / min, m<\/span>3<\/span> / h, gal / min<\/span><\/p><\/td><\/tr>
Pipe temperature measurement accuracy<\/span><\/p><\/td>
±3°C <\/span>±5.4°F<\/span> (liquid temperature of - 20 to + 50°C, <\/span>- 4 to + 122°F<\/span>)<\/span> ±5°C <\/span>±9°F<\/span> (liquid temperature of 50 to + 120°C, <\/span>122 to 248°F<\/span>)<\/span> (ambient operating temperature of 25°C <\/span>77°F<\/span>)<\/span>*4<\/span><\/p><\/td><\/tr>
Wiring specifications<\/span><\/p><\/td>
Power supply<\/span><\/p><\/td>
DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)<\/span><\/p><\/td><\/tr>
I/O<\/span><\/p><\/td>
When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block<\/span><\/p><\/td><\/tr>
Input/Output (Selectable)<\/span><\/p><\/td>
Output (ch.1/ch.2)<\/span><\/p><\/td>
Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less<\/span>*7<\/span><\/p><\/td><\/tr>
Analog output (ch.1/ch.2)<\/span><\/p><\/td>
Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less<\/span>*7<\/span><\/p><\/td><\/tr>
External input (ch.2)<\/span><\/p><\/td>
Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more<\/span>*7<\/span><\/p><\/td><\/tr>
Rating<\/span><\/p><\/td>
Power voltage<\/span><\/p><\/td>
20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)<\/span><\/p><\/td><\/tr>
Current consumption<\/span><\/p><\/td>
When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less<\/span><\/p><\/td><\/tr>
Environmental resistance<\/span><\/p><\/td>
Enclosure rating<\/span><\/p><\/td>
IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)<\/span><\/p><\/td><\/tr>
Ambient temperature<\/span><\/p><\/td>
- 20 to + 60°C <\/span>- 4.0 to 140 °F<\/span> (no freezing)<\/span>*2<\/span><\/p><\/td><\/tr>
Relative humidity<\/span><\/p><\/td>
5 to 90%RH (no condensation)<\/span><\/p><\/td><\/tr>
Vibration resistance<\/span><\/p><\/td>
10 to 55 Hz, compound amplitude 1.5 mm <\/span>0.06"<\/span>, XYZ axes 2 hours for each axis<\/span><\/p><\/td><\/tr>
Shock resistance<\/span><\/p><\/td>
100 m/s<\/span>2<\/span> , 16 ms pulse, XYZ axes, 1000 times for each axis<\/span><\/p><\/td><\/tr>
Dimensions<\/span><\/p><\/td>
Main unit size: 218.5 mm × 66.9 mm × 70.7 mm <\/span>8.60" × 2.63" × 2.78"<\/span><\/p><\/td><\/tr>
Main unit: Approx. 1.0 kg<\/span> Upper/lower bracket: Approx.1.5 kg (including sub unit)<\/span><\/p><\/td><\/tr><\/tbody><\/table><\/div><\/h3><\/div>","short_description":"
KEYENCE's FD-R Series Clamp-on Ultrasonic Liquid (Water) Flow Meter (sensor) is designed for pipes as large as 8". Installation is easy and requires only a screwdriver. The device can be mounted to a variety of materials including stainless steel, iron, copper, PVC, and resin. Both flow and temperature monitoring is possible for a wide variety of liquids\u2014from water (including pure water) to oil, chemicals, and high-pressure liquids\u2014at temperatures between -4°F and +248°F. <\/span><\/span><\/div>
<\/span><\/span><\/div>
The device does not come into contact with the liquid, so there is no risk of liquid-based corrosion or degradation, reducing maintenance time and costs. The rugged metal construction includes an easy-to-read indicator light, and data can be recorded directly on the device. The IP69K enclosure rating and NEMA4X compliance make this sensor both highly reliable and convenient for indoor and outdoor use.<\/span><\/span><\/div>
<\/span><\/div>
Mounting and Integration<\/h3>
Clamp-On the Outside of a Pipe<\/li>
No Pipe Modification (Non-Invasive)<\/li>
No Downtime for hot-tap insertion installations or inline metering installations<\/li>
Easily Secure with 4 or 6 Screws<\/li>
Bracket Ensures Correct Mounting by Anyone<\/li><\/ul>
Highly Versatile Water metering for Any Situation<\/h3>
Measure Water, DI Water, Oils, Chemicals, Product, etc.<\/li>
External pipe mount to Stainless, Iron, Copper, PVC, Resin, etc.<\/li>
Precise Monitoring with Accuracy of ±2.0% of RD<\/li>
Integrated Temperature Monitoring<\/li>
AC/DC Compatibility<\/li><\/ul>
Significant Reduction in Installation Time and Costs<\/h3>
No loss of production during Installation through non-invasive installation<\/li>
No Special Knowledge, Tools, or Contractors Needed<\/li>
No Risk of Contamination, Leaks, or Pressure Loss<\/li>
Install in Minutes with a Standard Screwdriver<\/li>
Keyence Liquid Ultrasonic Flow Meter FD-R Series (FD-H32, FD-R50, FD-R80, FD-R125, FD-R-200)
$1,200.00 - $4,500.00
$1,500.00
$2,200.00
$3,000.00
$4,500.00
$1,200.00 $1,300.00
Out of stock Out of stock Out of stock Out of stock Out of stock
KEYENCE's FD-R Series Clamp-on Ultrasonic Liquid (Water) Flow Meter (sensor) is designed for pipes as large as 8". Installation is easy and requires only a screwdriver. The device can be mounted to a variety of materials including stainless steel, iron, copper, PVC, and resin. Both flow and temperature monitoring is possible for a wide variety of liquids—from water (including pure water) to oil, chemicals, and high-pressure liquids—at temperatures between -4°F and +248°F.
The device does not come into contact with the liquid, so there is no risk of liquid-based corrosion or degradation, reducing maintenance time and costs. The rugged metal construction includes an easy-to-read indicator light, and data can be recorded directly on the device. The IP69K enclosure rating and NEMA4X compliance make this sensor both highly reliable and convenient for indoor and outdoor use.
Mounting and Integration
Clamp-On the Outside of a Pipe
No Pipe Modification (Non-Invasive)
No Downtime for hot-tap insertion installations or inline metering installations
Easily Secure with 4 or 6 Screws
Bracket Ensures Correct Mounting by Anyone
Highly Versatile Water metering for Any Situation
Measure Water, DI Water, Oils, Chemicals, Product, etc.
External pipe mount to Stainless, Iron, Copper, PVC, Resin, etc.
Precise Monitoring with Accuracy of ±2.0% of RD
Integrated Temperature Monitoring
AC/DC Compatibility
Significant Reduction in Installation Time and Costs
No loss of production during Installation through non-invasive installation
No Special Knowledge, Tools, or Contractors Needed
No Risk of Contamination, Leaks, or Pressure Loss
Install in Minutes with a Standard Screwdriver
Built-In Predictive Maintenance
Meter Attribute Selection
Select Meter Attribute Selection
Choose Quantity
+ Add to Cart Loading…
Product Details
Supported pipe materials
Metal / resin*1
Supported fluids
Various liquids (i.e. water, oils, chemicals)*1
Supported fluid temperature
- 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface)*2
Maximum rated flow
Rated flow velocity range: 5.0 m/s Flow rate range (Typical): 1 1/2" (40 A): 400 L / min 100 gal / min 24 m3/ h) 2" (50 A): 600 L / min 150 gal / min 36 m3 / h
Zero cut: 0.3 m/s (default)*3 Flow rate (Typical): 36 L / min 9 gal / min 2.4 m3 / h
Zero cut: 0.3 m/s (default)*3 Flow rate (Typical): 90 L / min 24 gal / min 5.4 m3/h
Zero cut: 0.3 m/s (default)*3 Flow rate (Typical): 220 L / min 60 gal / min 12 m3/h
Zero cut: 0.3 m/s (default)*3 Flow rate (Typical): 570 L / min 150 gal / min 36 m3 / h
Display method
Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator
Display update cycle
Approx. 3 Hz
Display resolution
0.1 / 1 (L / min)
1 (L / min)
Response time
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)
Measurement accuracy
Between 20 and 100% of F.S. : ±2.0% of RD*4*5 Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5
Protection circuit
Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output
Zero point error
±0.5% of F.S.*4*6
Hysteresis
Variable
Flow units
L / min, m3 / h, gal / min
Integrated flow unit display
1 / 10 / 100 / 1000 / 10000 (L)
Pipe temperature measurement accuracy
±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F) ±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F) (ambient operating temperature of 25°C 77°F)*4
Wiring specifications
Power supply
DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)
I/O
When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block
Input/Output (Selectable)
Output (ch.1/ch.2)
Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7
Analog output (ch.1/ch.2)
Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less*7
External input (ch.2)
Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7
Rating
Power voltage
20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)
Current consumption
When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less
Environmental resistance
Enclosure rating
IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)
Ambient temperature
- 20 to + 60°C - 4.0 to 140 °F (no freezing)*2
Relative humidity
5 to 90%RH (no condensation)
Vibration resistance
10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis
Shock resistance
100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis
Dimensions
Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78"